ABG - Arterial Blood gas - taking a sample

An ABG sample has to be taken directly in person to the lab, and handed over to a technician in person. You cannot send it with the normal samples, or put it in a pod!
Thus, before you begin, make sure you have ice ready, tell someone on the ward what you are doing, and make sure somebody is ready to take the sample in person to the lab. You have approximately 15 minutes to get the sample to the lab.

Samples are usually taken from the radial artery, but you can also use the femoral and brachial arteries
When sending off the sample you must record what % O2 the patient is on (if any)
 

Introduction

Introduce / check right patient / explain procedure / check anticoagulation therapy / gain consent. The procedure s used to check levels of oxygen and carbon dioxide in the blood. It is also used to check acid/base balance. Explain to the patient that knowing these levels helps asses what treatment is best. If the patient is on anti-coagulant therapy you won’t change the way you do the procedure, but note that it will probably take a lot longer for them to stop bleeding afterwards!
Wash your hands

Equipment

Go and get your equipment. You will need – an ABG pack – this has the syringe, needle, a bung, and the syringe cap – ice, swabs, cotton wool bud, bag to put sample in, forms to go with sample, plaster. Don’t forget to clean out your tray before you put all this stuff in it!
Ice is used because it slows down the metabolism of red cells. if the sample is left for a long time (e.g. transferred to another hospital) then the use of oxygen by cells can lead to a falsely low O2 level in the sample. 

Preparation

Open out the ABG pack – you should find a syringe already with heparin in it. You need to put the needle on the syringe (put it on, do a ¼ turn, then pull off the cap and you should be ok). One you have done this, you can squirt all of the heparin out of the syringe (just do this with the cap half on, it doesn’t really matter where the heparin goes)– this leaves a very small amount in the needle which will help prevent clots.
Wash/alco gel, then put gloves on

Allen's Test

You need to check the collateral circulation to the hand – a rare complication of blood sampling is that you may end up occluding the radial artery (e.g. as a result of a clot), and thus you should test collateral circulation to the hand to prevent ischaemia of the hand if this event were to occur. Get the patient to make a fist. Find both the radial and ulnar arteries, then press down on them to occlude them for a few seconds. Ask the patient to relax their hand and show their palm. It will appear blanched. Let go of the ulnar artery but keep holding down the radial. The hand should turn red again as it is perfused. As long as this perfusion takes no longer than 10-15 seconds, then there is adequate perfusion of the hand via the ulnar artery, and you are able to continue. If there is not adequate perfusion, you are unable to use the radial artery for this procedure.
Feel the radial artery - you are going to use the radial artery. Have a really good feel of it – you are going to go in where the pulse is strongest – this is a different place on different people! Once you are happy you have got a good place, then swab the area (leave it 30 seconds to dry). Don’t touch the area again!

Collect Sample

Go in! – hold the syringe a bit like a pen.you want to go in at 45’. You should go ‘up’ the artery, i.e. towards the elbow. Insert the needle slowly. The syringe should now rise by itself. You only need 1-2 ml. Once you are happy you have got this amount, take the needle out, and put cotton wool on straight away! This will need to be held on (either by the patient or by you, or if you really have to you can tape it down hard) for at least 2-3 minutes, possibly 10 (or longer if on warfarin).
If you don’t get into the artery, you can try again – as long as you don’t withdraw the needle fully from the skin, you can poke around – but remember this is very painful!
Bung it! – stick the needle into the bung, whilst you deal with the cotton wool. Once you are happy with the cotton wool situation, you can put the needle (and bung) in the sharps bin.
The cap – the ABG kit comes with a cap that allows air but not blood through it. Put the cap on the syringe once you have taken the needle off. Flick the syringe to get all the air to the top, and then you can squeeze the air out. As soon as you get a drop of blood in the cap, stop squeezing! The cap is to allow you to squeeze air out without spilling blood. Once all the air is out, you should mix the sample to make sure the anti-coagulant is thoroughly mixed with the sample.  You should label up the sample and use the ice, and make sure it gets delivered in person and all that.

Finishing off

Finish off – check the site isn’t still bleeding, and check the patient is comfortable. Once you are happy its no longer bleeding, you can stick a plaster on (helps prevent infection)

- See more at: http://almostadoctor.co.uk/content/osces/skills-and-procedures/abg-arterial-blood-gas-taking-sample#sthash.RvQpNvu3.dpuf